Islanding detection is an important technique for micro-grid connected/isolated control. Traditional passive island detection reliability is bad, while active method have negative influence on power quality, so a new method based on chaotic property was proposed. The main reasons of chaos phenomenon during micro-grid conversion process in both connected/isolated operation modes are studied in this paper. Chaos theory is applied to reconstruct the phase space of voltage waveform in the micro-grid conversion process. At the same time, the maximum Lyapunov exponents of the voltage waveform are extracted. The results prove that typical chaos phenomenon occurs during the conversion process. And finally, the simulations of micro-grid isolated detection are carried out in the platform of RTLAB, proved the islanding detection is effective based on the chaotic characteristics. Through introducing the chaos characteristics of connected/isolated micro-grid, blind areas of the island detection can be decreased, improve the accuracy and reliability of the island detection.
机译:孤岛检测是微电网连接/隔离控制的一项重要技术。传统的无源孤岛检测可靠性较差,而有源方法对电能质量有负面影响,因此提出了一种基于混沌特性的新方法。研究了并网/隔离两种运行方式下微电网转换过程中出现混沌现象的主要原因。应用混沌理论重构了微电网转换过程中电压波形的相空间。同时,提取电压波形的最大李雅普诺夫指数。结果证明,在转换过程中会发生典型的混沌现象。最后,在RTLAB平台上对微电网隔离检测进行了仿真,证明了基于混沌特性的孤岛检测是有效的。通过引入连接/隔离的微电网的混沌特性,可以减少孤岛检测的盲区,提高孤岛检测的准确性和可靠性。