Frequency modulation of a series resonant dual active bridge to minimize the circulating reactive currents in the high frequency link

机译:串联谐振双有源桥的频率调制,以最大程度地减少高频链路中的循环无功电流

获取原文
获取原文并翻译 | 示例

摘要

A frequency modulation scheme is proposed for a Capacitor-Inductor-Inductor-Capacitor (CLLC) Resonant Dual Active Bridge (RDAB) that relies on dynamic retuning of the resonant capacitors to the switching frequency as it is modulated. The proposed modulation scheme greatly reduces the circulating reactive currents in the High Frequency Link (HFL) by operating at a range of fixed discrete switching frequencies. A Triple Phase Shift (TPS) modulation scheme is used in between the discrete steps of switching frequencies and capacitances. In this paper, a mathematical analysis is presented of the RDAB and the proposed modulation scheme is compared to all of the existing modulation schemes. The CLLC RDAB is implemented in simulation and the simulation results demonstrate the effectiveness of the proposed modulation scheme at decreasing the circulating reactive currents, and therefore, greatly decreasing the conduction losses of the converter at light load, while maintaining its soft switching capability.
机译:针对电容器-电感-电感-电容器(CLLC)谐振双有源桥(RDAB),提出了一种调频方案,该方案依赖于谐振电容器在调制时动态调整到开关频率。所提出的调制方案通过在一定范围内的固定离散开关频率下工作,大大降低了高频链路(HFL)中的循环无功电流。在开关频率和电容的离散步骤之间使用三相移(TPS)调制方案。在本文中,对RDAB进行了数学分析,并将提出的调制方案与所有现有的调制方案进行了比较。在仿真中实现了CLLC RDAB,仿真结果证明了所提出的调制方案在降低循环无功电流方面的有效性,因此,在保持轻载能力的同时,在轻载条件下大大降低了转换器的传导损耗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号