This article analyzes the impact of electronic loads, particularly CRT, LCD and LED televisions, regarding the measurements of reactive power in energy meters of Brazilian Electric Power companies and consequently the influence of those measurements in the reactive surplus Billing (Reactive Energy Excess and Demand Energy Excess). Later, the values obtained from the energy meter are compared to the CPT power components. For the reactive surplus calculation, it is considered not only the reactive power, but also the distortion in the system. It is concluded that the harmonic distortion causes significant interference in measurements of reactive power in energy meters, and that the calculation of reactive power surplus through power factor allows certain inconsistencies in the billing.
机译:本文分析了电子负载(特别是CRT,LCD和LED电视)对巴西电力公司电能表中无功功率测量的影响,以及这些测量对无功剩余计费中的影响(无功电能过剩和需求能量)过量)。随后,将从电表获得的值与CPT功率分量进行比较。对于无功剩余计算,不仅要考虑无功功率,还要考虑系统中的失真。结论是,谐波失真对电能表中无功功率的测量产生了重大干扰,并且通过功率因数计算无功功率过剩在计费方面存在某些不一致之处。