首页> 外文会议>2016 17th International Conference on Harmonics and Quality of Power >Analysis of the STATCOM use to mitigate the effects of voltage sags on the wind farms operation. A study case
【24h】

Analysis of the STATCOM use to mitigate the effects of voltage sags on the wind farms operation. A study case

机译:对STATCOM的使用进行分析,以减轻电压骤降对风电场运行的影响。一个学习案例

获取原文
获取原文并翻译 | 示例

摘要

The increasing on the interest for the renewable energy stimulated Brazil to invest on the development of the wind energy. However, the increased integration of wind power on the interconnected national system brings some complications due to the reliability of this source of power. This work shows, through simulations, the consequences that voltage variations on the grid can cause to the operation of a wind farm. The simulation was made in two parts. Firstly, three scenarios that may cause failures on the wind farm operation are simulated: a fault on the grid, variations on the wind speed and a resistive load of high power. The scenarios of fault on the grid and the resistive load showed variations strong enough to cause the shut-down of the wind farm on. Thus, the second part of the simulations evaluated the use of the compensation device, the STATCOM, to mitigate the negative effects caused to the wind farm, where it was partially effective.
机译:对可再生能源的兴趣的增加刺激了巴西投资于风能的发展。但是,由于这种电力来源的可靠性,风电在相互关联的国家系统上的集成度不断提高,带来了一些复杂性。这项工作通过仿真显示了电网电压变化可能导致风电场运行的后果。仿真分为两部分。首先,模拟了可能导致风电场运行失败的三种情况:电网故障,风速变化和高功率电阻负载。电网故障和电阻性负载的情况表明变化足够大,足以导致关闭风电场。因此,模拟的第二部分评估了补偿装置STATCOM的使用,以减轻对风电场造成的负面影响,该风电场部分有效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号