With the advancement in technology, in order to use simple and effective technique for reducing harmonics in the input supply current, multi-pulse techniques are widely being used in high power applications like aircrafts electric power systems and in the electrochemical industries. For systems where isolation is not a major concern, multi-pulse converters provide the best solution. With the increase in pulse number, Characteristic Harmonics are greatly reduced but, at the cost of complexity and expenses. In this paper, two differently wound 18-pulse Differential Delta configured Auto Transformer Rectifier Units(ATRU) are being analyzed and discussed here. Their operating principle is analyzed; the harmonics analysis of the input ac current and output dc voltage of the ATRUs is done, the RMS of every winding are calculated. Simulation models were built in MATLAB in order to see the results of both the systems, and at the end, for the complete evaluation and experimental verification, 2kW Power experimental prototype was built.
机译:随着技术的进步,为了使用简单有效的技术来减少输入电源电流中的谐波,多脉冲技术被广泛用于飞机电源系统等大功率应用以及电化学行业。对于隔离不是主要问题的系统,多脉冲转换器提供了最佳解决方案。随着脉冲数的增加,特征谐波被大大降低,但是以复杂性和费用为代价。本文分析和讨论了两种不同缠绕的18脉冲差分Delta配置的自动变压器整流器(ATRU)。分析了它们的工作原理;对ATRU的输入交流电流和输出直流电压进行谐波分析,计算出每个绕组的RMS。为了查看两个系统的结果,在MATLAB中构建了仿真模型,最后,为了进行完整的评估和实验验证,构建了2kW Power实验原型。