Short-term voltage stability problem (STVSP) is a serious threat to receiving-end power systems which are short of reactive power reserves. This paper discusses how to plan the size of shunt capacitor banks (SCB) in a receiving-end power system to achieve a maximum voltage stability margin. The local generators and SCB are two important reactive power resources in receiving-end power systems. The size of SCB affects the reactive power output of generators in steady state. Furthermore, it impacts the voltage stability margin. It is necessary to obtain the best size of SCB, because an over-design or an under-design is not capable to eliminate the STVSP. We propose a voltage sag severity index to determine the size of SCB in this work. The proposed method has been tested on a typical receiving-end power system to work out the best size of SCB and then to verify its effectiveness through time-domain simulation.
机译:短期电压稳定性问题(STVSP)对无功功率储备不足的接收端电力系统构成严重威胁。本文讨论如何规划接收端电源系统中并联电容器组(SCB)的大小,以实现最大的电压稳定性裕度。本地发电机和SCB是接收端电力系统中的两个重要无功功率资源。 SCB的大小会影响稳态下发电机的无功输出。此外,它影响电压稳定性裕度。必须获得最佳的SCB尺寸,因为过度设计或欠设计不能消除STVSP。我们提出电压暂降严重性指标,以确定这项工作中的SCB的大小。该方法已经在典型的接收端电源系统上进行了测试,以得出最佳尺寸的SCB,然后通过时域仿真验证其有效性。