首页> 外文会议>2015 IEEE Magnetics Conference >Basic consideration of winding arrangement of amorphous transformers for MW-class DC-DC converters
【24h】

Basic consideration of winding arrangement of amorphous transformers for MW-class DC-DC converters

机译:MW级DC-DC转换器的非晶变压器绕组布置的基本考虑

获取原文

摘要

An interleaved winding arrangement is examined in this article for use in MW-class DC-DC converters. The frequency dependences of winding resistance of interleaved and non-interleaved winding arrangements are compared experimentally using a 10-kW test amorphous transformer. It is demonstrated that copper loss of non-interleaved winding significantly increases although the operating frequency is below 1 kHz. Hence, the MW-class amorphous transformer requires an interleaved winding to reduce copper loss.
机译:本文研究了交错式绕组布置,以用于MW级DC-DC转换器。使用10 kW测试的非晶变压器,通过实验比较了交错式和非交错式绕组布置的绕组电阻的频率相关性。结果表明,尽管工作频率低于1 kHz,但非交错绕组的铜损却显着增加。因此,MW级非晶变压器需要交错绕组以减少铜损。