Shore power connection that is a practice whereby shore-side electrical power is provided to vessels when a ship is at berth in a port is set to play a major role in shaping the future energy requirements of the commercial shipping industry. Short-circuit level compatibility of the system is a problem when a ship power system is connected to a shore electrical distribution system. A method that is able to evaluate the shore-side and ship-side impedances and determine the prospective short-circuit current level is essential. This paper aims at presenting a methodology for calculating the short-circuit current in the shore power connection system. Two analysis models, including IEC std. 61363-1 and IEC std. 60909-0 combined with IEC std. 60909-0, are developed and used in this paper for short-circuit current analysis. Performance of the proposed method is validated by short-circuit current calculation results gathered from several visiting ship scenarios in a practical shore power connection system. The proposed method can provide engineers with useful information about the prospective magnitude of short-circuit currents as well as on the effect of shore supply on ship power system, which will assist them in ensuring short-circuit level compatibility and allowing the selection and setting of protective devices.
机译:岸电连接是一种惯例,当船舶停泊在港口时,岸上电力将提供给船只,这将在确定未来商业航运业的能源需求中发挥重要作用。当船舶电力系统连接到岸上配电系统时,系统的短路水平兼容性是个问题。能够评估岸侧和船侧阻抗并确定预期短路电流水平的方法至关重要。本文旨在提供一种计算岸电连接系统中短路电流的方法。两种分析模型,包括IEC标准。 61363-1和IEC标准60909-0与IEC标准结合本文开发并使用60909-0进行短路电流分析。该方法的性能通过在实际岸电连接系统中从多个来访船舶场景中收集的短路电流计算结果进行验证。所提出的方法可以为工程师提供有关短路电流的预期大小以及岸电对船舶电力系统的影响的有用信息,这将有助于他们确保短路等级的兼容性,并允许选择和设置保护装置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号