首页> 外文会议>2015 IEEE Eindhoven PowerTech >Scenario analysis of generic feeders to assess the adequacy of residential LV-grids in the coming decades
【24h】

Scenario analysis of generic feeders to assess the adequacy of residential LV-grids in the coming decades

机译:通用馈线的方案分析,以评估未来几十年内家用低压电网的适用性

获取原文
获取原文并翻译 | 示例

摘要

The energy transition will bring large changes to residential load profiles. In order to assess whether the current low voltage (LV)-grids are capable of handling these changes, future scenario analysis must be used to assess the grid adequacy. To this end, an approach is proposed, incorporating scenario-based household load modelling, LV-feeder clustering and probabilistic load flow calculations. All combinations of independent scenarios on the drivers of change in the residential load have been assessed with probabilistic load flow calculations . Generic feeders are chosen, which are representative for the LV-grid of a Dutch distribution network operator. The scenario assessment shows the chances of overloading and/or exceeding of the voltage limits for the LV-feeders over different time horizons and scenarios. The approach can also be used to assess the main scenario drivers and grid parameters responsible for changes in the future adequacy of the LV-grid.
机译:能源过渡将给住宅的负荷曲线带来巨大变化。为了评估当前的低压(LV)电网是否能够应对这些变化,必须使用未来的情景分析来评估电网的充足性。为此,提出了一种方法,该方法结合了基于情景的家庭负荷建模,低压馈线聚类和概率潮流计算。通过概率潮流计算评估了住宅负荷变化驱动因素的独立情景的所有组合。选择通用馈线,它们代表荷兰配电网络运营商的低压电网。情景评估显示了在不同的时间范围和情景下,LV馈线过载和/或超过电压限制的可能性。该方法还可用于评估负责LV电网未来适应性变化的主要情景驱动因素和电网参数。