首页> 外文会议>2014 IEEE 16th International Conference on Harmonics and Quality of Power >Harmonic resonance in power systems - a documented case
【24h】

Harmonic resonance in power systems - a documented case

机译:电力系统中的谐波谐振-有案可查的案例

获取原文
获取原文并翻译 | 示例

摘要

Harmonic resonance occurs in a power system when the power system natural frequency corresponds to the frequency of a source of harmonic current. This paper studies a real case of power system harmonic resonance that resulted in failure of 20-kV capacitor bank fuses. The load current harmonics are measured and analyzed to investigate the individual harmonics of the current and then by using the system impedance frequency characteristic, the voltage harmonic distortion and the corresponding capacitor current are determined. Calculation of the power system natural frequencies are given for various configurations of system shunt capacitance and results of the power system harmonic current and voltage on the capacitor fuse blown is studied. The paper proposes a criterion for the proper size of capacitor to put in service according to system frequency characteristic and current harmonics.
机译:当电力系统的固有频率对应于谐波电流源的频率时,在电力系统中会发生谐波谐振。本文研究了导致20 kV电容器组熔断器故障的电力系统谐波谐振的真实案例。测量并分析负载电流谐波,以研究电流的各个谐波,然后利用系统阻抗频率特性,确定电压谐波失真和相应的电容器电流。给出了系统并联电容各种配置的电力系统固有频率的计算,并研究了电容器熔断时电力系统谐波电流和电压的结果。根据系统的频率特性和电流谐波,提出了合适尺寸的电容器投入使用的准则。