The study reveals that the heat transfer varisation for film condensation on horizontal low integral-fin tubes,measuring the experimental determinatiion based on the high flow rates,departed the condensation heat transfer coefficient,associated with the numerical calculation to get the changeable trend along the tube.the investigation of the condensation heat transfer for pure fluids and the azeotropic refrigerant shows that the heat flux change violently along the tube,at the range of the experiment paramenters.the value of the heat flux at the range of the experiment parameters.The value of the heat flux at the outlet is 81.3~83.7% compared to inlet.Both beat transfer coefficient and overall heat transfer coefficient of inside and outside tube show a faint change along the tube.The velocity of the water in the tube is an important factor which affects the uniformity of heat flux along the tube;the temperature of the water at the inlet of the tube is slightly affected,comparatively.The conclusion of the investigation can be used to guide the designs of the condenstation heat transfer experiment on horizontal single-tube and the heat exchanger.
机译:研究表明,在水平低整翅管上进行膜冷凝的传热变化,根据高流量进行实验测定,得出冷凝传热系数,并结合数值计算得出沿管的变化趋势。对纯流体和共沸制冷剂的冷凝传热研究表明,在实验参数范围内,热通量沿管道剧烈变化。在实验参数范围内的热通量值。出口处的热通量是入口处的81.3〜83.7%。管内外拍的传热系数和总传热系数都沿管显示微弱的变化。管中水的流速是一个重要因素这会影响沿管子的热通量的均匀性;相比之下,管子入口处的水温会受到轻微影响。研究结论可为指导卧式单管换热器冷凝器传热实验的设计提供指导。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号