In interventional cardiology, three-dimensional anatomical and functional information of the cardiac chambers, e.g. the left ventricle, would have an important impact on diagnosis and therapy. With the technology of C-arm CT it is possible to reconstruct intraprocedural 3-D images from angiographic projection data. Due to the long acquisition time of several seconds, motion-related artifacts, like blurring or streaks, occur. Therefore, the heart dynamics need to be taken into account in order to improve the reconstruction results. When it comes to the evaluation of different motion estimation and compensation algorithms and techniques of motion analysis, there is still a lack of comparability of the final reconstructions and motion parameters between the research groups. Since the results are heavily dependent on the applied motion pattern and simulation parameters, the experiments are not reproducible. We try to overcome these problems by providing varying left heart ventricle phantom datasets, consisting of projection images as well as extracted surface meshes. Up to now, there are six different datasets available: one with a normal sinus rhythm, one with a normal sinus rhythm and a catheter, one with a lateral wall defect of the ventricle, two with a lateral contraction phase shift and one without any motion. The existing datasets are based on a phantom similar to the 4D XCAT phantom with a contrasted left ventricle, myocardium, and aorta. The geometry calibration and acquisition protocol from a real clinical C-arm scanner are used. A webpage is provided where the data and the necessary files are publicly available for download at conrad.stanford.edu/data/heart.
机译:在介入性心脏病学中,心腔的三维解剖和功能信息,例如左心室,将对诊断和治疗产生重要影响。借助C臂CT技术,可以从血管造影投影数据重建过程内3-D图像。由于数秒的采集时间很长,因此会出现与运动相关的伪像,例如模糊或条纹。因此,需要考虑心脏动力学以改善重建结果。在评估不同的运动估计和补偿算法以及运动分析技术时,研究组之间仍然缺乏最终重构和运动参数的可比性。由于结果在很大程度上取决于所应用的运动模式和仿真参数,因此实验无法重现。我们试图通过提供不同的左心室幻象数据集来克服这些问题,这些数据集由投影图像以及提取的表面网格组成。到目前为止,有六种不同的数据集:一个具有正常的窦性心律,一个具有正常的窦性心律和导管,一个具有心室的侧壁缺损,两个具有侧向收缩相移并且一个没有任何运动。现有的数据集基于类似于4D XCAT幻影的幻影,左心室,心肌和主动脉形成对比。使用来自实际临床C型臂扫描仪的几何形状校准和采集协议。提供了一个网页,可在conrad.stanford.edu/data/heart上公开下载数据和必要的文件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号