In the initial period of power system restoration, the generator unit regulating ability is limited. charging transformer without load would cause sympathetic inrush current. This would leads to mal-tripping of the protective relay that result in the failure of the restoration. Based on the equivalent circuit of two shunt-wound transforms, the mathematical representation between sympathetic inrush and main operating parameters is deduced using network analysis approach. After that, the influence of load power factor on sympathetic inrush current is analyzed deeply. The process of sympathetic inrush based on the model of actual situation is simulated and the analytical results is proved to is validated. The conclusion of this paper is valuable in understanding the generating reasons of sympathetic inrush current and avoiding restoration failure in initial period of power system restoration.
机译:在电力系统恢复的初期,发电机组的调节能力受到限制。给无负载的变压器充电会引起同感的浪涌电流。这将导致保护继电器误跳闸,从而导致恢复失败。基于两个并联绕线变换的等效电路,利用网络分析方法推导了同感涌流与主要工作参数之间的数学表示。之后,深入分析了负载功率因数对交感涌流的影响。以实际情况为模型,对同情突入过程进行了模拟,并验证了分析结果的有效性。本文的结论对于理解和电涌流的产生原因,避免电网恢复初期的恢复失败具有重要的参考价值。