首页> 外文会议>2012 IEEE Power Electronics and Machines in Wind Applications. >Comparison of different cooling systems for Doubly-Fed Wind Generator
【24h】

Comparison of different cooling systems for Doubly-Fed Wind Generator

机译:双馈风力发电机不同冷却系统的比较

获取原文
获取原文并翻译 | 示例

摘要

This paper presents the numerical simulation of flow-thermal coupling for 2 MW Doubly-Fed Induction Wind Generator (DFIG). With fundamental assumptions and corresponding boundary conditions, the number of grid is reduced to save calculation time. The temperature of internal air for different cooling system configuration is calculated with commercial FEA software FLUENT without assumption. Four cooling system configurations of DFIG are presented, analyzed and compared in details. The best cooling system configuration of DFIG has been found and will be used into our DFIG production.
机译:本文介绍了2 MW双馈感应风力发电机(DFIG)的流热耦合数值模拟。通过基本假设和相应的边界条件,减少了网格数量以节省计算时间。无需假设,使用商用FEA软件FLUENT计算用于不同冷却系统配置的内部空气温度。详细介绍,分析和比较了DFIG的四种冷却系统配置。找到了DFIG的最佳冷却系统配置,并将其用于我们的DFIG生产中。