首页> 外文会议>2012 IEEE International Conference on Automation and Logistics >DC network connecting of switched reluctance generator system
【24h】

DC network connecting of switched reluctance generator system

机译:开关磁阻发电机系统的直流网络连接

获取原文
获取原文并翻译 | 示例

摘要

The paper presents the developed Switched Reluctance generator system with DC network connecting to loads and the storage batteries. The generator system is made up of three-phase 12/8 structure Switched Reluctance generator, three-phase asymmetrical bridge power converter and the digital controller by the core of Freescale MCF5213 microprocessor clocked at 80MHz. The closed-loop control scheme of output voltage is described. The process of estalishing output voltage is tested. The sudden adding load and sudden unload experiments are made. It is shown that the time of estalishing output voltage is very short, and the recovery time of the output voltage is also short under sudden adding load and sudden unload. The distributing Switched Reluctance generator system provides the DC electrical power to the loads and the redundant electrical power can be used to charge the storage batteries.
机译:本文介绍了开发的带直流网络的开关磁阻发电机系统,该系统连接到负载和蓄电池。发电机系统由三相12/8结构的开关磁阻发电机,三相非对称桥式功率转换器和由频率为80MHz的Freescale MCF5213微处理器的核心组成的数字控制器组成。描述了输出电压的闭环控制方案。测试了建立输出电压的过程。进行突然的增加负荷和突然的卸载实验。结果表明,在突然增加负载和突然卸载的情况下,建立输出电压的时间非常短,并且输出电压的恢复时间也很短。分布式开关磁阻发电机系统向负载提供直流电,冗余电可用于为蓄电池充电。