Control of three phase inverter for AC motor drive with small DC-link capacitor fed by single phase AC source

机译:用单相交流电源馈电的小型直流母线电容器控制交流电机驱动的三相逆变器

获取原文

摘要

If a small DC-link capacitor is used in the DC-link fed by single phase AC source, the DC-link voltage fluctuates severely with twice of the source frequency. To handle this fluctuation, the concept of ‘average voltage constraint’ is proposed in this study. On the basis of the concept, a flux weakening scheme generating d-axis current reference (idsr*) for Interior Permanent Magnet Synchronous Machine (IPMSM) is devised. And, q-axis current reference (iqsr*) is modified for the unity power factor operation to AC source. The proposed scheme has been applied to inverter driven 1 kW compressor of an air-conditioner. From the experimental results, it has been verified that the compressor operates well at required operating condition regardless of the severe fluctuation of DC-link voltage due to the reduced DC-link capacitor. Also the frequency spectrum of the AC source current reveals that the harmonics of the source current meet IEC 61000-3-2 Class A and that the overall power factor is above 97% without any additional circuit such as an input filter and the power factor correction circuit.
机译:如果在单相交流电源馈电的直流母线中使用小型直流母线电容器,则直流母线电压会以电源频率的两倍剧烈波动。为了应对这种波动,本研究提出了“平均电压约束”的概念。基于该概念,设计了一种用于内部永磁同步电机(IPMSM)的产生d轴电流参考(idsr *)的磁通减弱方案。并且,修改了q轴电流参考(iqsr *),以对AC电源进行统一的功率因数操作。拟议的方案已应用于空调的逆变器驱动的1 kW压缩机。从实验结果可以证明,无论由于减少的直流母线电容器而导致的直流母线电压剧烈波动,压缩机都能在要求的工况下良好运行。此外,交流电源电流的频谱表明,电源电流的谐波符合IEC 61000-3-2 Class A,总功率因数高于97%,而无需任何其他电路(例如输入滤波器和功率因数校正)电路。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号