首页> 外文会议>2012 6th Asia-Pacific Conference on Environmental Electromagnetics. >Research of the Electromagnetic compatibility problems caused as putting heavy and weak current facilities together in the subway system
【24h】

Research of the Electromagnetic compatibility problems caused as putting heavy and weak current facilities together in the subway system

机译:地铁系统中大电流和弱电流设施组合在一起引起的电磁兼容性问题的研究

获取原文
获取原文并翻译 | 示例

摘要

Based on CST, models of the heavy current facilities in the subway system have been built and the simulation has been completed to acquire the radiation of EMI. By comparing the results of the simulation with the corresponding results of the actual measurement, the models are modified until the simulation of the models could mainly reflect the situation of Electromagnetic field around the heavy current facilities correctly. With the procedure of actual measurement, modeling, simulation, analysis and modification, the shortest distance between the heavy and weak current facilities in the subway station in the normal working condition could be proposed. A more reasonable layout of all facilities could also be acquired so that the resource of the rooms could be saved and the administration of the whole station could be easier.
机译:基于CST,建立了地铁系统中大电流设施的模型,并完成了仿真以获取EMI辐射。通过将模拟结果与实际测量的相应结果进行比较,对模型进行修改,直到模型的模拟能够主要正确反映大电流设施周围的电磁场情况为止。通过实际测量,建模,仿真,分析和修改的过程,可以提出正常工作条件下地铁车站大电流设施和弱电流设施之间的最短距离。还可以获取所有设施的更合理布局,从而节省房间资源并简化整个站点的管理。