首页> 外文会议>2002 ASME International Mechanical Engineering Congress and Exposition , Nov 17-22, 2002, New Orleans, Louisiana >QUANTITATIVE DETERMINATION OF THE STABILITY OF IMPLANT-BONE INTERFACE USING RESONANCE FREQUENCY ANALYSIS
【24h】

QUANTITATIVE DETERMINATION OF THE STABILITY OF IMPLANT-BONE INTERFACE USING RESONANCE FREQUENCY ANALYSIS

机译:共振频率分析定量确定IMP骨界面的稳定性

获取原文
获取原文并翻译 | 示例

摘要

It is important to have a quantitative method to establish a standard way to measure stability and osseointegration of implants. Among other benefits, these measurements would provide information leading to the prediction of healing time around the implant and the monitoring of the health of the implant's interface. The dental industry has been looking for non-destructive methods to measure implant integration within the bone. In previous studies, resonance frequency analysis revealed a clear relationship between resonance frequency measurements and stiffness of the implant interface and the effective length of the implant. These studies have examined only one mode of vibration or have suffered from measurement difficulties. Furthermore, no study has evaluated the damping properties of the interface and surrounding tissues. This paper describes the development of an instrument capable of capturing and measuring information to characterize the process of dental implant osseointergration. The parameters needed to measure stability and osseointegration of implants are the stiffness of the implant components (which are a function of their geometry and material composition) and the stiffness and damping properties of the implant-bone interface and surrounding tissues. The instrument developed provides valuable information about the stiffness and damping properties of the implant-bone interface obtained through resonance frequency analysis with torsional, longitudinal and transverse vibration. Experimental, analytical, and finite element analysis results are presented.
机译:重要的是要有一种定量方法来建立测量植入物稳定性和骨整合度的标准方法。除其他好处外,这些测量将提供信息,从而可预测植入物周围的愈合时间并监视植入物界面的健康状况。牙科行业一直在寻找非破坏性方法来测量植入物在骨内的整合。在以前的研究中,共振频率分析揭示了共振频率测量值与植入物界面的刚度和植入物的有效长度之间的明确关系。这些研究仅检查了一种振动模式或遭受了测量困难。此外,还没有研究评估界面和周围组织的阻尼特性。本文介绍了一种能够捕获和测量信息以表征牙种植体骨整合过程的仪器的开发。测量植入物的稳定性和骨整合所需的参数是植入物组件的刚度(这是其几何形状和材料成分的函数)以及植入物-骨界面和周围组织的刚度和阻尼特性。开发的仪器提供了有关通过扭转,纵向和横向振动的共振频率分析获得的植入物-骨界面的刚度和阻尼特性的有价值的信息。给出了实验,分析和有限元分析结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号