Several investigations have been conducted concerning vortexing and air entrainment in horizontal suction lines from pump sumps [1 through 11]. All of these investigations are for conditions where the water level remains above the top of the horizontal suction line. Recent changes to the D. C. Cook nuclear plant emergency operating procedures has resulted in the need to allow the water level in the Refueling Water Storage Tank (RWST) to drop below the top of the horizontal pump suction line for short periods of time. Since the available data were not applicable to this situation, hydraulic testing was conducted using a 1:4 geometric scale model of the RWST and associated pump suction piping. Several water levels and flow rates were tested with the water level both above and below the top of the suction pipe. The test results show that for Froude numbers less than about 0.33, the water level can be lowered below the top of the pipe without significant air entrainment.
机译:已经进行了一些有关泵油罐[1至11]的水平吸入管路中的涡旋和空气夹带的研究。所有这些调查都是针对水位保持在水平吸水线顶部以上的条件。库克(D. C.)库克核电站紧急运行程序的最新更改导致需要在短时间内使加油水储罐(RWST)中的水位下降到水平泵吸水线以下。由于可用数据不适用于这种情况,因此使用RWST和相关的泵吸入管道的1:4几何比例模型进行了液压测试。使用吸水管顶部上方和下方的水位测试了几个水位和流量。测试结果表明,对于弗劳德数小于约0.33的情况,可以将水位降低到管道顶部以下,而不会明显夹带空气。