【24h】

SHELL AND TUBE HEAT EXCHANGER RELIABILITY STUDY

机译:壳管式换热器可靠性研究

获取原文
获取原文并翻译 | 示例

摘要

In 1997, heat exchanger tube failures accounted for 31% of the unplanned downtime in Lyondell's Gulf Coast plants. This resulted in over dollar 12MM of unplanned production interruptions. A multi-disciplinary team studied the tube failure modes and developed a systematic program to improve the heat exchanger reliability. The team issued recommendations in the areas of heat exchanger design, construction, operation, maintenance and inspection. This paper mainly discusses the three critical areas surrounding the reliability of heat exchanger tubes. They are tube testing, strategy on retubing exchangers during turnarounds and design improvements.
机译:1997年,在Lyondell的墨西哥湾沿岸工厂,换热管故障占计划外停机的31%。这导致了超过12毫米的计划外生产中断。一个多学科小组研究了管道故障模式,并开发了系统程序来提高热交换器的可靠性。该小组在热交换器的设计,建造,操作,维护和检查领域提出了建议。本文主要讨论围绕换热管可靠性的三个关键领域。他们是管道测试,周转期间对换热器进行换管的策略以及设计改进。