The paper describes a method of using the transfer function of a given system to calculate the shielding efficiency (SE) of a protective screen with the help of measurements conducted in the time domain. A high voltage Electromagnetic Pulse Simulator (EMPS) creates the required pulse fields. The radiated field in the working zone of the simulator is measured by a V-conical sensor. Evaluation of the shielding efficiency in the frequency domain is carried out by deconvoluting the measured electric field applying Fast Fourier Transform (FFT) techniques. Different materials are compared for their SE over a wide frequency range from 0 to 100MHz, which is the spectrum of the generated impulse.
机译:本文介绍了一种使用给定系统的传递函数来在时域进行测量的情况下计算保护屏的屏蔽效率(SE)的方法。高压电磁脉冲模拟器(EMPS)创建所需的脉冲场。模拟器工作区域中的辐射场由V型锥形传感器测量。通过使用快速傅立叶变换(FFT)技术对测量的电场进行反卷积,可以对频域中的屏蔽效率进行评估。在0到100MHz的宽频率范围内比较了不同材料的SE,这是产生的脉冲的频谱。