Medical linear accelerators used to treat various forms of cancers are operated at a number of different energies. A by-product of the high-energy photons produced by accelerators is activation of components within the machine itself and its surrounding bunker. The activation products pose radiological and regulatory challenges during the operation of the accelerator as well as when it is time for final decommissioning. The Varian TrueBeam is a new state-of-the-art linear accelerator now operating in the Canadian market. There is currently limited information on the production of its activation products and the resulting impacts on operation and decommissioning. In this paper, the activation products in the Varian TrueBeam accelerator are experimentally determined by performing gamma spectroscopy using a portable high purity germanium detector. A total of 11 isotopes are identified which includes ~(24)Na, ~(28)Al, ~(56)Mn, ~(57)Ni, ~(64)Cu, ~(66)Cu, ~(85)Br, ~(122)Sb, ~(124)Sb, ~(187)W, and ~(228)Ac. The half-lives of these isotopes range from 2.3 minutes to 60.2 days. Combining the CNSC isotope exemption quantities found in the Canadian Nuclear Substance and Radiation Device regulations and the isotopic quantities determined during the gamma spectroscopy, the aggregate exemption quantity for the accelerator at any given time is determined. After 36 hours, a decommissioning case can be presented to the CNSC for the disposal of the accelerator or shipment to a non-licensee in the USA.
机译:用于治疗各种形式癌症的医用线性加速器以多种不同的能量运行。加速器产生的高能光子的副产品是激活机器本身及其周围的掩体中的组件。激活产品在加速器运行期间以及最终退役时会带来放射学和监管方面的挑战。瓦里安TrueBeam是一种最新的最新线性加速器,现已在加拿大市场上运行。目前,有关其活化产品的生产及其对运行和退役的影响的信息有限。在本文中,瓦里安TrueBeam加速器中的活化产物是通过使用便携式高纯度锗检测器进行伽马光谱学实验确定的。共鉴定出11种同位素,包括〜(24)Na,〜(28)Al,〜(56)Mn,〜(57)Ni,〜(64)Cu,〜(66)Cu,〜(85)Br ,〜(122)Sb,〜(124)Sb,〜(187)W和〜(228)Ac。这些同位素的半衰期为2.3分钟至60.2天。结合加拿大核物质和辐射装置法规中发现的CNSC同位素免除量和伽马能谱测定期间确定的同位素量,可以确定在任何给定时间的促进剂总免除量。 36小时后,可以将退役案例提交给CNSC,以处置加速器或运往美国的非许可方。

著录项

  • 来源
  • 会议地点 Knoxville TN(US)
  • 作者单位

    University of Ontario Institute of Technology: 2000 Simcoe St. N. Oshawa, ON. L1H 7K4;

    University of Ontario Institute of Technology: 2000 Simcoe St. N. Oshawa, ON. L1H 7K4;

    University of Ontario Institute of Technology: 2000 Simcoe St. N. Oshawa, ON. L1H 7K4;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号