Fourteen Fe-Si anodes containing 0,22 to 18,4wt/o silicon, having a ferrite structure with a minimum of 5% nodular and dot-shaped graphite, were tested as per "Short term test" - Det norske Veritas - standard. The effects of six-month anode exposure to 25g/L Na_2SO_4 electrolyte and 5, 20, 40, 60 and 80A/m~2 current density were analysed. The experimental results prove that at the usual current density of 20A/m~2, the minimum specifie anodie consumption is recorded for 14,44/18,4wt/o silicon content, being of 0,2/0,4kg/A.yr. But a little less silicon content gives a severe increase of the anodic consumption and at about 10wt/o silicon the determined specific consumption is of the same order of magnitude with that of the carbon steel in the experimental conditions. The specific consumption has a signifieant increase for 80A/m~2, getting double.
机译:按照“短期测试”(Det norske Veritas)的标准测试了十四个含铁0.22至18.4wt / o的Fe-Si阳极,这些阳极具有至少5%的结核和点状石墨的铁素体结构。分析了六个月阳极暴露于25g / L Na_2SO_4电解质和5、20、40、60和80A / m〜2电流密度下的影响。实验结果证明,在通常的电流密度为20A / m〜2时,硅含量为14,44 / 18,4wt / o的最小指定阳极消耗量为0,2 / 0,4kg / A.yr。 。但是少一点的硅含量会严重增加阳极消耗,在大约10wt / o的硅条件下,确定的比消耗与实验条件下碳钢的比消耗处于相同的数量级。比消耗显着增加80A / m〜2,增加一倍。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号