首页> 外文会议>11th International Conference on Electrical Machines and Systems(第11届国际电机与系统会议)论文集 >Analysis and Comparison of two Control Strategies for Three-Phase Series-Parallel UPS
【24h】

Analysis and Comparison of two Control Strategies for Three-Phase Series-Parallel UPS

机译:三相串联-并联UPS两种控制策略的分析与比较

获取原文

摘要

In this paper, two control strategies for three-phase series-parallel uninterruptible power supplies are compared. A series-parallel UPS consists of a parallel and a series converter. In this topology, most power required by load is supplied directly from ac line during standby mode. Therefore the overall efficiency is higher than that of a conventional UPS. Traditionally, the control strategy of these structures was based on voltage control of series converter and current control of parallel converter. However, recently an opposite strategy has been proposed, i.e., voltage control of parallel converter and current control of series converter. This paper compares these two control strategies. The comparison is made based on different performance criteria like seamless transition between backup and standby modes, dynamic performance, complexity of reference generation and size of filters in two strategies.
机译:本文比较了三相串并联不间断电源的两种控制策略。串联-并联UPS由并联和串联转换器组成。在这种拓扑中,负载所需的大部分功率在待机模式下直接从交流线路提供。因此,总体效率高于传统UPS。传统上,这些结构的控制策略基于串联转换器的电压控制和并联转换器的电流控制。但是,最近提出了相反的策略,即,并联转换器的电压控制和串联转换器的电流控制。本文比较了这两种控制策略。比较是基于不同的性能标准进行的,例如备用和备用模式之间的无缝过渡,动态性能,参考生成的复杂性以及两种策略中的过滤器大小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号