In order to simulate the effects of lightning and switching transients on power lines, coupling and decoupling network (CDN) is necessary for performing surge tests on electrical and electronic equipment. This paper presents a particular analysis of the circuit of CDN and design details according to the requirement of the standard IEC 61000-4-5. The CDN circuit is simulated by electromagnetic transients program (EMTP) to select component values. Simulation results also show that increasing of decoupling capacitance or inductance can obviously reduce the residual surge voltage on the power line inputs of the CDN. Based on the voltage drop control and residual surge voltage limiting, smaller decoupling inductance and relatively larger decoupling capacitance should be chosen if EUT has a higher rated current. The CDN developed according to the simulation results comply with the design specifications well.
机译:为了模拟雷电和开关瞬变对电力线的影响,耦合和去耦网络(CDN)对于在电气和电子设备上执行浪涌测试是必要的。本文根据IEC 61000-4-5标准的要求,对CDN电路进行了特殊分析,并详细介绍了设计细节。 CDN电路通过电磁瞬态程序(EMTP)进行仿真以选择组件值。仿真结果还表明,去耦电容或电感的增加可以明显降低CDN电源线输入上的残余浪涌电压。基于电压降控制和剩余浪涌电压限制,如果EUT具有较高的额定电流,则应选择较小的去耦电感和相对较大的去耦电容。根据仿真结果开发的CDN符合设计规范。