A new catalytic kinetic spectrophotometric method for the determination of trace amount of cobalt(Ⅱ) in microemulsion medium has been developed. This method is based on the catalytic effect of cobalt(Ⅱ) on the hydrogen peroxide(H2O2) oxidation of hydroxyphenyl fluorone (DBH-PF) in the presence of cetyltrimethylammonium bromide (CTMAB) microemulsion medium and NaOH medium. All the variables were studied in order to optimize the reaction conditions. Beer's law is obeyed over the range of 0~0.12 ng/mL and the detection limit is 4.86×10-13 g/mL. The method has been successfully applied in determination of Co(Ⅱ) in water sample with satisfactory results.
机译:建立了一种新的催化动力学光度法测定微乳液介质中痕量钴(Ⅱ)的方法。该方法是基于十六烷基三甲基溴化铵(CTMAB)和NaOH介质中钴(Ⅱ)对羟苯基芴酮(DBH-PF)的过氧化氢(H2O2)氧化的催化作用。研究了所有变量以优化反应条件。在0〜0.12 ng / mL范围内符合比尔定律,检出限为4.86×10-13 g / mL。该方法已成功应用于水样中钴(Ⅱ)的测定,结果令人满意。