首页> 外文OA文献 >The Fatigue Behaviour of Tension Lap Spliced Reinforced Concrete Beams Strengthened with Fibre Reinforced Polymer Wrapping
【2h】

The Fatigue Behaviour of Tension Lap Spliced Reinforced Concrete Beams Strengthened with Fibre Reinforced Polymer Wrapping

机译:纤维增强聚合物包裹加固拉伸搭接钢筋混凝土梁的疲劳性能。

摘要

Many reinforced concrete structures containing lap splices were constructed before modern bond and fatigue design codes came into existence and are subjected to fatigue loading, which may lead to a bond failure even when the applied load is far below the ultimate load for a bond failure under a monotonic loading. Fatigue loads result in a deterioration of the bond interaction between the steel and concrete and interrupt the force transfer mechanism resulting in an increased deflection, an increased number of cracks and their widths, and a decreased load carrying capacity of reinforced concrete elements of structures. Some of these structures require strengthening to enhance their bond strength at lap splices.This study was aimed at increasing our understanding of the behaviour of the bond between the steel bar and the concrete along the lap splice region for structures subjected to cyclic loading. An additional aim of the study was to investigate the effect of fatigue loading on the bond between concrete and steel, and the ability of the new high and low modulus fiber-reinforced polymer (FRP) sheets to enhance the fatigue performance of a tension lap splice. Fifty three beams were cast and tested under monotonic and fatigue loading. The beams dimensions were 2200 mm in length, 350 mm in height and 250 mm in width. Each beam was reinforced with two 20M bars lap spliced in the constant moment region of the tension zone and two 10M bars in the compression zone outside the constant moment region. The test variables were the concrete cover, the presence or absence of FRP wrapping, the type of the FRP wrapping glass or carbon fiber-reinforced polymer (GFRP or CFRP), the type of loading and the fatigue load range. The minimum load applied was 10% of the static bond capacity of the specimen. The maximum load was varied to obtain fatigue lives between 1,000 and 1,000,000 cycles. The test frequency for all cyclic tests was 1.3 Hz.The results of the tests under monotonic load showed that the GFRP wrapped beams had an increase in bond strength of approximately 25% compared to the unwrapped beams for each of the concrete covers. However, the CFRP wrapped beams had a percentage increase in bond strength that decreased as the concrete cover increased. The CFRP wrapped beams had increases in bond strength of 71%, 60% and 44% compared to the unwrapped beams for concrete covers of 20 mm, 30 mm and 50 mm, respectively.The results of the tests under fatigue load showed that all beams failed by a bond failure except for those beams that exceeded the fatigue life limits for a longitudinal bar. As expected, these beams failed by fatigue rupture of the longitudinal steel bars. The GFRP and CFRP sheets increased the fatigue strength (measured as the applied load range for a given fatigue life) of the wrapped beams for all concrete covers compared to that of the unwrapped beams. The longitudinal splitting cracks for the FRP wrapped beams were finer in width and larger in number compared to those cracks for the unwrapped beams.A crack growth model was developed to calculate the fatigue life of the bond specimens and to calculate the slip and the deflection due to stress changes in the steel and concrete due to cracking, and compare it to the measured slip and deflection. There is also a good agreement between the calculated number of cycles with the actual fatigue data for all different wrapping conditions and all different concrete cover thicknesses. Also, only a small amount of the inelastic slip and the inelastic deflection are due to the stress changes in the steel and concrete due to splitting cracking. The remaining inelastic slip and inelastic deflection which are due to deformation of the concrete in front of the steel rebar lugs is much larger.
机译:许多包含搭接接头的钢筋混凝土结构是在现代的粘结和疲劳设计规范出现之前建造的,并且要承受疲劳载荷,即使当施加的载荷远低于极限载荷下的粘结破坏的最终载荷时,也可能导致粘结失效。单调加载。疲劳载荷导致钢与混凝土之间的键相互作用恶化,并中断力传递机制,从而导致挠度增加,裂缝及其宽度增加,并且钢筋混凝土结构构件的承载能力降低。这些结构中的一些需要加强以提高搭接接头处的粘结强度。本研究旨在增进我们对承受循环载荷的结构沿搭接接头区域的钢筋和混凝土之间粘结性能的了解。这项研究的另一个目的是研究疲劳载荷对混凝土和钢之间粘结的影响,以及新型高低模量纤维增强聚合物(FRP)片增强张力搭接接头疲劳性能的能力。 。铸造了53根梁,并在单调和疲劳载荷下进行了测试。横梁的尺寸为长2200毫米,高350毫米,宽250毫米。每个梁都用两个20M钢筋搭接在张力区的恒定弯矩区域上,两个10M钢筋在压缩区的恒定弯矩区域外进行加固。测试变量是混凝土覆盖层,是否存在FRP包裹,FRP包裹玻璃或碳纤维增强聚合物(GFRP或CFRP)的类型,载荷的类型和疲劳载荷范围。施加的最小载荷为样品静态粘结能力的10%。改变最大载荷以获得1,000至1,000,000次循环的疲劳寿命。所有循环试验的试验频率为1.3 Hz。在单调载荷下的试验结果表明,与未包裹的梁相比,GFRP包裹的梁的粘结强度增加了约25%。但是,CFRP包裹的梁的粘结强度百分比增加,但随着混凝土覆盖层的增加而减小。与20mm,30mm和50mm的混凝土覆盖层相比,CFRP包裹的梁的粘结强度分别比未包裹的梁提高了71%,60%和44%。疲劳载荷下的测试结果表明,所有梁由于粘结失效而导致失效,除了那些超过纵向钢筋疲劳寿命极限的梁。不出所料,这些梁由于纵向钢筋的疲劳断裂而失效。与未包裹的梁相比,GFRP和CFRP板增加了所有混凝土盖的包裹梁的疲劳强度(在给定的疲劳寿命下,按施加的载荷范围衡量)。与未包裹的FRP包裹的梁相比,FRP包裹的梁的纵裂裂缝在宽度上更细,数量更大。建立了裂纹扩展模型以计算粘结试样的疲劳寿命并计算出滑移和挠度观察裂纹引起的钢和混凝土应力变化,并将其与测得的滑移和挠度进行比较。在所有不同的包裹条件和所有不同的混凝土覆盖层厚度下,计算出的循环次数与实际疲劳数据之间也存在很好的一致性。而且,只有少量的非弹性滑移和非弹性挠曲是由于开裂引起的钢和混凝土应力变化所致。由于钢筋突缘前面的混凝土变形而产生的剩余无弹性滑移和无弹性挠曲要大得多。

著录项

  • 作者

    Alyousef Rayed;

  • 作者单位
  • 年度 2016
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号