Evaluation of the economic simplified boiling water reactor human reliability analysis using the SHARP framework

机译:使用sHaRp框架评估经济简化沸水反应堆人体可靠性分析

摘要

General Electric plans to complete a design certification document for the Economic Simplified Boiling Water Reactor to have the new reactor design certified by the United States Nuclear Regulatory Commission. As part of the design process, the design control document was produced in 2006, and it includes a description of the human reliability analysis performed as part of the reactor's probabilistic risk analysis. The problem is to verify the claim that the human reliability analysis was performed according to the Systematic Human Action Reliability Procedure (SHARP). The seven step method was compared directly to the actions documented by General Electric. Each step was identified and the actions within the steps were identified and evaluated to verify that no rules of SHARP were in contention with the analysis. The reason for using the SHARP method instead of revisions and improvements of the SHARP method was determined and more detailed analysis will be performed in later phases of the reactor design, but the human reliability analysis quantified with general human error probabilities was still a conservative estimate of the human reliability.
机译:通用电气计划完成经济简化沸水反应堆的设计认证文件,以使新的反应堆设计获得美国核监管委员会的认证。作为设计过程的一部分,设计控制文件于2006年编制,其中包括对作为反应堆概率风险分析的一部分进行的人员可靠性分析的描述。问题是要验证有关根据系统性人类行为可靠性程序(SHARP)进行了人类可靠性分析的说法。将七步法直接与通用电气记录的行为进行了比较。确定每个步骤,并确定和评估步骤中的操作,以验证没有SHARP规则与分析发生冲突。确定了使用SHARP方法而不是对SHARP方法进行修订和改进的原因,并且将在反应堆设计的后续阶段中进行更详细的分析,但是使用一般人为错误概率进行量化的人为可靠性分析仍然是保守估计。人类的可靠性。

著录项

  • 作者

    Dawson Phillip Eng;

  • 作者单位
  • 年度 2007
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号