An LLCL-filter is becoming more attractive than an LCL-filter as the interface between the grid-tied inverter and the grid due to possibility of reducing the copper and the magnetic materials. The efficiency of the LLCL-filter based single-phase grid-tied inverter also excites interests for many applications. The operation of the switches of the VSI is various with different modulation methods, which lead to different efficiencies for such a single-phase grid-tied inverter system, and therefore important research has been carried out on the effect of the choice of PWM schemes. Then power losses and efficiencies of the LLCL-filter and the LCL-filter based single-phase grid-tied inverters are analyzed and compared under the discontinuous unipolar, the dual-buck and the bipolar modulations. Results show that the efficiency of LLCL-filter based inverter system is higher than the LCL- filter based independent on the modulation method adopted. Experiments on a 2 kW prototype are in good agreement with results of the theoretical analysis
机译:作为并网逆变器和电网之间的接口,LLC滤波器比LCL滤波器更具吸引力,因为它可以减少铜和磁性材料。基于LLCL滤波器的单相并网逆变器的效率也引起了许多应用的兴趣。 VSI开关的操作因调制方式不同而异,导致这种单相并网逆变器系统的效率不同,因此对PWM方案的选择效果进行了重要研究。然后,在不连续的单极,双降压和双极调制下,分析并比较了基于LLCL滤波器和基于LCL滤波器的单相并网逆变器的功率损耗和效率。结果表明,与采用的调制方法无关,基于LLCL滤波器的逆变器系统的效率要高于基于LCL滤波器的逆变器系统。 2 kW原型的实验与理论分析的结果非常吻合

著录项

  • 作者单位
  • 年度 2014
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 入库时间 2022-08-20 21:02:01

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号