首页> 外文OA文献 >A Novel Repair Technique for the Internal Thermal Control System Dual-Membrane Gas Trap
【2h】

A Novel Repair Technique for the Internal Thermal Control System Dual-Membrane Gas Trap

机译:内部热控制系统双膜气阱的新型修复技术

摘要

A dual-membrane gas trap is currently used to remove gas bubbles from the Internal Thermal Control System (ITCS) coolant on board the International Space Station (ISS). The gas trap consists of concentric tube membrane pairs, comprised of outer hydrophilic tubes and inner hydrophobic fibers. Liquid coolant passes through the outer hydrophilic membrane, which traps the gas bubbles. The inner hydrophobic fiber allows the trapped gas bubbles to pass through and vent to the ambient atmosphere in the cabin. The gas trap was designed to last for the entire lifetime of the ISS, and therefore was not designed to be repaired. However, repair of these gas traps is now a necessity due to contamination from the on-orbit ITCS fluid and other sources on the ground as well as a limited supply of flight gas traps. This paper describes a novel repair technique that has been developed that will allow the refurbishment of contaminated gas traps and their return to flight use.
机译:目前,双膜气阱用于从国际空间站(ISS)上的内部热控制系统(ITCS)冷却剂中除去气泡。气阱由同心管膜对组成,该对膜由外亲水管和内疏水纤维组成。液体冷却剂通过外部亲水膜,从而捕获气泡。内部疏水性纤维允许捕获的气泡通过并排放到机舱中的周围大气中。气阱设计为在ISS的整个使用寿命内都可以使用,因此不能进行维修。但是,由于在轨ITCS流体和地面其他来源的污染以及飞行气体捕集器的供应有限,现在必须对这些气体捕集器进行维修。本文介绍了一种已开发的新型维修技术,该技术将允许对受污染的气体疏水阀进行翻新并使其恢复飞行使用。