Influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery

机译:白内障手术后角膜后散光对假晶状体术后屈光散光的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

BackgroundTo examine the influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery.MethodsThe study enrolled 64 pseudophakic eyes of 50 patients (71.8 ± 9.9 years old, mean ± standard deviation) who had undergone phacoemulsification with non-toric IOL implantation. Refractive astigmatism was measured using an auto ref-keratometer with a 0.01- diopter (D) scale. Two types of corneal astigmatism were calculated using anterior segment optical coherence tomography; keratometric and total corneal astigmatism. Keratometric astigmatism was obtained based on anterior corneal curvature alone and total corneal astigmatism was calculated using both anterior and posterior corneal curvatures. The difference between refractive and corneal astigmatism was computed as the vector difference using 1) refractive and keratometric astigmatism and 2) refractive and total corneal astigmatism.ResultsThe mean refractive, keratometric, and total corneal astigmatism was 0.92 ± 0.48 D, 0.87 ± 0.44 D, and 0.94 ± 0.46 D, respectively. The difference between refractive and keratometric astigmatism (0.70 ± 0.40 D, mean vector of 0.30 D axis 164°) was significantly larger than the difference between refractive and total corneal astigmatism (0.63 ± 0.38 D, mean vector of 0.12 D axis 137°) (P = .019).ConclusionsThe difference between refractive and total corneal astigmatism, calculated using both anterior and posterior corneal curvatures, was significantly smaller than the difference between refractive and keratometric astigmatism using anterior corneal astigmatism alone, implying that the latter overestimates the true postoperative refractive astigmatism and can cause cylindrical inaccuracy after cataract surgery.
机译:背景研究白内障手术后假晶状体眼角膜后散光对术后屈光散光的影响。方法本研究共纳入了50例(71.8±9.9岁,平均±标准差)经非扭转性IOL植入超声乳化术的64例假晶状体眼。 。使用自动屈光度计以0.01屈光度(D)的刻度测量屈光散光。使用前段光学相干断层扫描技术计算了两种类型的角膜散光。角膜散光和全角膜散光。仅根据前角膜曲率获得角膜散光,并使用前后角膜曲率计算总角膜散光。使用1)屈光度和角膜散光和2)屈光度和角膜散光,将屈光度和角膜散光的差计算为矢量差。结果平均屈光度,角膜散光和总角膜散光分别为0.92±0.48 D,0.87±0.44 D,和0.94±0.46D。屈光度和角膜散光的差异(0.70±±0.40 D,平均矢量为0.30 D轴164°)显着大于屈光度和角膜散光的差异(0.63±±0.38 D,平均为0.12 D轴137°)( P = .019)。结论使用前和后角膜曲率计算的屈光度和总角膜散光的差异明显小于仅使用前角膜散光的屈光度和角膜散光的差异,这表明后者高估了真实的术后屈光度散光,并可能导致白内障手术后出现圆柱状误差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号