Seismic Assessment of Pre-1970s Reinforced Concrete Structure

机译:1970年代以前的钢筋混凝土结构的地震评估

摘要

Reinforced concrete structures designed in pre-1970s are vulnerable under earthquakes due to lack of seismic detailing to provide adequate ductility. Typical deficiencies of pre-1970s reinforced concrete structures are (a) use of plain bars as longitudinal reinforcement, (b) inadequate anchorage of beam longitudinal reinforcement in the column (particularly exterior column), (c) lack of joint transverse reinforcement if any, (d) lapped splices located just above joint, and (e) low concrete strength. Furthermore, the use of infill walls is a controversial issue because it can help to provide additional stiffness to the structure on the positive side and on the negative side it can increase the possibility of soft-storey mechanisms if it is distributed irregularly. Experimental research to investigate the possible seismic behaviour of pre-1970s reinforced concrete structures have been carried out in the past. However, there is still an absence of experimental tests on the 3-D response of existing beam-column joints under bi-directional cyclic loading, such as corner joints. As part of the research work herein presented, a series of experimental tests on beam-column subassemblies with typical detailing of pre-1970s buildings has been carried out to investigate the behaviour of existing reinforced concrete structures. Six two-third scale plane frame exterior beam-column joint subassemblies were constructed and tested under quasi-static cyclic loading in the Structural Laboratory of the University of Canterbury. The reinforcement detailing and beam dimension were varied to investigate their effect on the seismic behaviour. Four specimens were conventional deep beam-column joint, with two of them using deformed longitudinal bars and beam bars bent in to the joint and the two others using plain round longitudinal bars and beam bars with end hooks. The other two specimens were shallow beam-column joint, one with deformed longitudinal bars and beam bars bent in to the joint, the other with plain round longitudinal bars and beam bars with end hooks. All units had one transverse reinforcement in the joint. The results of the experimental tests indicated that conventional exterior beam-column joint with typical detailing of pre-1970s building would experience serious diagonal tension cracking in the joint panel under earthquake. The use of plain round bars with end hooks for beam longitudinal reinforcement results in more severe damage in the joint core when compared to the use of deformed bars for beam longitudinal reinforcement bent in to the joint, due to the combination of bar slips and concrete crushing. One interesting outcome is that the use of shallow beam in the exterior beam-column joint could avoid the joint cracking due to the beam size although the strength provided lower when compared with the use of deep beam with equal moment capacity. Therefore, taking into account the low strength and stiffness, shallow beam can be reintroduced as an alternative solution in design process. In addition, the presence of single transverse reinforcement in the joint core can provide additional confinement after the first crack occurred, thus delaying the strength degradation of the structure. Three two-third scale space frame corner beam-column joint subassemblies were also constructed to investigate the biaxial loading effect. Two specimens were deep-deep beam-corner column joint specimens and the other one was deep-shallow beam-corner column joint specimen. One deep-deep beam-corner column joint specimen was not using any transverse reinforcement in the joint core while the two other specimens were using one transverse reinforcement in the joint core. Plain round longitudinal bars were used for all units with hook anchorage for the beam bars. Results from the tests confirmed the evidences from earthquake damage observations with the exterior 3-D (corner) beam-column joint subjected to biaxial loading would have less strength and suffer higher damage in the joint area under earthquake. Furthermore, the joint shear relation in the two directions is calibrated from the results to provide better analysis. An analytical model was used to simulate the seismic behaviour of the joints with the help of Ruaumoko software. Alternative strength degradation curves corresponding to different reinforcement detailing of beam-column joint unit were proposed based on the test results.
机译:1970年代以前设计的钢筋混凝土结构由于缺乏地震细节无法提供足够的延展性而容易受到地震的影响。 1970年代以前的钢筋混凝土结构的典型缺陷是:(a)使用普通钢筋作为纵向钢筋,(b)梁纵向钢筋在柱子(特别是外柱)中的锚固不足,(c)缺少横向接缝钢筋(如果有), (d)位于接头上方的搭接接头,以及(e)混凝土强度低。此外,填充墙的使用是一个有争议的问题,因为它可以帮助为结构的正侧提供额外的刚度,而在负侧则可以增加软储层结构(如果分布不规则)的可能性。过去已经进行了实验研究,以研究1970年代以前的钢筋混凝土结构的可能地震行为。但是,在双向循环载荷(例如角接缝)下,现有梁柱节点的3-D响应仍缺乏实验测试。作为本文介绍的研究工作的一部分,已经对梁柱子组件进行了一系列的实验测试,其中包括1970年代以前建筑物的典型细节,以研究现有钢筋混凝土结构的性能。在坎特伯雷大学结构实验室,在准静态循环荷载下构造并测试了六个三分之二的平面框架外梁柱联合子组件。改变了钢筋的细部和梁的尺寸,以研究它们对地震行为的影响。四个标本是传统的深梁柱节点,其中两个使用变形的纵向钢筋和弯曲到节点的梁,另外两个使用普通的圆形纵向钢筋和带有端钩的梁。其他两个标本是浅横梁柱节点,一个标本具有变形的纵梁和弯曲到该节点的横梁,另一个标本为平的圆形纵梁和具有端钩的横梁。所有单元的接缝处都有一个横向钢筋。实验结果表明,在地震作用下,传统的外部梁柱节点在1970年代以前具有典型的细节,在节点面板处会出现严重的对角拉伸裂缝。与使用弯曲的弯头和混凝土压碎相结合的变形的钢筋用于弯折到接头中的纵梁纵向钢筋相比,使用带有端钩的带端钩的普通圆钢会导致对接头核心的严重破坏。 。一个有趣的结果是,在外梁-柱节点中使用浅梁可以避免由于梁尺寸而引起的节点开裂,尽管与使用具有相同弯矩承载力的深梁相比,强度较低。因此,考虑到低强度和刚度,可以在设计过程中重新引入浅梁作为替代解决方案。另外,在接头芯中存在单个横向钢筋可以在发生第一次裂纹后提供额外的限制,从而延迟了结构的强度降低。还构造了三个三分之二的空间框架角梁-柱节点子组合件,以研究双轴加载效果。两个标本是深-深梁-角柱节点标本,另一个是深-浅梁-角柱节点标本。一个深-深梁-角柱接缝样品在接缝芯中未使用任何横向钢筋,而另外两个样品在接缝芯中未使用任何横向钢筋。平的圆形纵向钢筋用于所有带有横梁锚钩锚固的单元。测试结果证实了外部双角荷载的3-D(角)梁-柱节点在双轴荷载下的地震破坏观察的证据将具有较小的强度,并在地震作用下的接合区域遭受更大的破坏。此外,从结果校准了两个方向上的联合剪切关系,以提供更好的分析。借助Ruaumoko软件,使用分析模型来模拟接头的地震行为。根据试验结果,提出了对应于梁柱节点单元不同加固细节的替代强度退化曲线。

著录项

  • 作者

    Hertanto Eric;

  • 作者单位
  • 年度 2005
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号