首页> 美国政府科技报告 >Fatality Assessment and Control Evaluation (FACE) Report: Career Lieutenant Dies After Being Trapped in the Attic After Falling Though a Roof While Conducting Ventilation - Texas, FACE-F2011-20.
【24h】

Fatality Assessment and Control Evaluation (FACE) Report: Career Lieutenant Dies After Being Trapped in the Attic After Falling Though a Roof While Conducting Ventilation - Texas, FACE-F2011-20.

机译:死亡率评估和控制评估(FaCE)报告:职业中尉在进入通风后跌倒屋顶后被困在阁楼后 - 德克萨斯州,FaCE-F2011-20。

获取原文

摘要

On August 14, 2011, a 41-year-old career lieutenant died after falling through a roof and being trapped in an attic. The lieutenant was part of a two-man crew attempting to perform vertical ventilation of a two story multi-family apartment complex. The fire department had responded to multiple fires over the years at this apartment complex. The roof decking material was over 30 years old and would not meet the current building code. The fire on the first floor was quickly brought under control but had spread into the attic along the exterior wall and through the eaves. The fire had compromised the structural integrity of the roof decking material prior to the crew operating on the roof. When the lieutenant crossed over the peak of the roof to ventilate above the fire, he fell through the weakened roof and into the attic. His legs went through the ceiling of the second floor apartment while his body remained in the attic. He was wearing his self-contained breathing apparatus (SCBA) but was not wearing his facepiece and was overcome by the products of combustion. He was rescued by crews operating at the scene and transported to a local hospital where he died from his injuries.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号