首页> 美国政府科技报告 >Corrosion of Roof Bolt Steels in Missouri Lead and Iron Mine Waters
【24h】

Corrosion of Roof Bolt Steels in Missouri Lead and Iron Mine Waters

机译:密苏里铅,铁矿井水中锚杆钢的腐蚀

获取原文

摘要

As part of ongoing research to improve mine safety, the Bureau of Mines conducted research on the corrosion of friction rock stabilizer steels in five Missouri lead and iron mine waters. Electrochemical corrosion tests, including evaluation of pitting tendency, were performed on two types of high-strength, low-alloy (HSLA) steels and galvanized steel in four Missouri lead mine waters and one Missouri iron mine water. The tests were conducted at in-mine water temperatures in both air-saturated and deaerated waters. Static, weight-loss corrosion tests were also conducted on HSLA steel specimens in the five Missouri mine waters for a 2,900-h duration at average in-mine water temperatures and air-dissolved oxygen contents of 6 to 7 ppm. Corrosion rates determined by the weight-loss tests were roughly comparable with rates determined electrochemically in deaerated waters containing 0.3 to 0.5 ppm dissolved oxygen content. Passivation of specimen (nongalvanized) surfaces in air-saturated waters resulted in very low electrochemically determined corrosion rates. Pitting tendency was generally higher for both HSLA steels in air-saturated waters than in deaerated waters. Galvanized steel generally exhibited higher tendency to pitting in the deaerated waters than in the aerated mine waters.