Thermal igniters proposed by the Tennessee Valley Authority for intentional ignition of hydrogen in nuclear reactor containments have been tested in mixtures of air, hydrogen, and steam. The igniters, conventional diesel engine glow plugs, were tested in a 10.6 cubic foot pressure vessel with dry hydrogen concentrations from 4% to 29% hydrogen, and in steam fractions of up to 50%. Dry tests indicated complete combustion between 8% and 9% H2, and no combustion for concentrations below 5%. Steam tests were done with hydrogen volume fractions of 8%, 10%, and 12%. Steam concentrations of up to 30% consistently resulted in ignition. Most of the 40% steam fraction tests resulted in combustion. In a few isolated cases the 50% steam fraction tests indicated a pressure rise. Circulation of the mixture improved combustion in both the dry and the steam tests, most notably at low H2 concentrations. An analysis of the high steam fraction test data showed a high probability for the presence of small, suspended, water droplets in the test mixture. The suppressive influence of this condensation-generated fog on combustion is evaluated.