首页> 美国政府科技报告 >Measurement of the Central Ion and Electron Temperature of Tokamak Plasmas from the X-Ray Line Radiation of High-Z Impurity Ions
【24h】

Measurement of the Central Ion and Electron Temperature of Tokamak Plasmas from the X-Ray Line Radiation of High-Z Impurity Ions

机译:从高Z杂质离子的X射线辐射测量托卡马克等离子体的中心离子和电子温度

获取原文

摘要

This paper describes measurements of the central ion and electron temperature of tokamak plasmas from the observation of the 1s - 2p resonance lines, and the associated dielectronic (1s exp 2 nl - 1s2pnl, with n greater than or equal to 2) satellites, of helium-like iron (Fe XXV) and titanium (Ti XXI). The satellite to resonance line ratios are very sensitive to the electron temperature and are used as an electron temperature diagnostic. The ion temperature is deduced from the Doppler width of the 1s - 2p resonance lines. The measurements have been performed with high resolution Bragg crystal spectrometers on the PLT (Princeton Large Torus) and PDX (Poloidal Divertor Experiment) tokamaks. The details of the experimental arrangement and line evaluation are described, and the ion and electron temperature results are compared with those obtained from independent diagnostic techniques, such as the analysis of charge-exchange neutrals and measurements of the electron cyclotron radiation. The obtained experimental results permit a detailed comparison with theoretical predictions. (ERA citation 07:045305)