首页> 美国政府科技报告 >Hydraulic Performance of Pump Suction Inlets for Emergency Core Cooling Systems in Boiling Water Reactors.
【24h】

Hydraulic Performance of Pump Suction Inlets for Emergency Core Cooling Systems in Boiling Water Reactors.

机译:沸水堆应急堆芯冷却系统泵吸入口水力性能。

获取原文

摘要

The document reports on the hydraulic performance of representative Boiling Water Reactor Residual Heat Removal suction inlet configurations; Mark I and Mark II and III designs. Parameters of interest were air-ingestion, vortex tapes, pipe swirl, and pressure loss coefficient. Tests were conducted with nearly uniform and non-uniform inlet approach flows. Flows and submergences ranged from 2000 to 12000 gpm per pipe and 2 to 5 ft, respectively, giving a Froude number range from 0.17 to 1.06.