The effect of wall friction on magnetohydrodynamic generator performance is determined by introduction of a wall friction factor into the one-dimensional generator equations. This addition should be useful in improving generator analysis and determining optimum generator geometry. The curves presented can be used to determine the effects of changes in wall friction and generator performance. Wall friction has an increasing effect on the Mach number increases and a decreasing effect as the pressure drop across the generator increase. (Author)