The preflight preparation of the multilayer mirror fabrication and testing, integration and testing, and WSMR activities are described. Post-flight analysis shows that all payload systems and subsystems performed well within acceptable limits, with the sole exception of the light-blocking prefilters. Suggested corrective actions were discussed. Refurbishment and reflight are then described.