首页> 美国政府科技报告 >NASA (National Aeronautics and Space Administration) Powered Lift Facility Internally Generated Noise and Its Transmission to the Acoustic Far Field
【24h】

NASA (National Aeronautics and Space Administration) Powered Lift Facility Internally Generated Noise and Its Transmission to the Acoustic Far Field

机译:Nasa(美国国家航空航天局)动力提升设备内部产生的噪声及其向声学远场的传输

获取原文

摘要

Noise tests of NASA Lewis Research Center's Powered Lift Facility (PLF) were performed to determine the frequency content of the internally generated noise that reaches the far field. The sources of the internally generated noise are the burner, elbows, valves, and flow turbulence. Tests over a range of nozzle pressure ratios from 1.2 to 3.5 using coherence analysis revealed that low frequency noise below 1200 Hz is transmitted through the nozzle. Broad banded peaks at 240 and 640 Hz were found in the transmitted noise. Aeroacoustic excitation effects are possible in this frequency range. The internal noise creates a noise floor that limits the amount of jet noise suppression that can be measured on the PLF and similar facilities.