首页> 美国政府科技报告 >Gas-jet and tangent-slot film cooling tests of a 12.5 deg cone at Mach number of 6.7
【24h】

Gas-jet and tangent-slot film cooling tests of a 12.5 deg cone at Mach number of 6.7

机译:气流和切线槽薄膜冷却试验,12.5度锥体,马赫数为6.7

获取原文

摘要

Tests were conducted in the Langley 8-Foot High Temperature Tunnel to determine the aerothermal effects of gaseous nitrogen-coolant ejection on a 3-ft base-diameter, 12.5 degree half-angle cone. Free-stream Mach number, total temperature, and unit Reynolds number per foot were 6.7, 3300 deg R, and 1.4 million, respectively. Two coolant ejection noses were tested, an ogive frustum with a forward-facing 0.8-in radius gas-jet tip, and a 3-in radius hemisphere with a 0.243-in high rearward-facing tangent slot. Data include surface pressures and heating rates, shock shapes, and shock-layer profiles; results are compared with no-cooling data obtained with 1-in and 3-in radius solid noses. Surface pressures were reduced with gas-jet ejection but were affected little by tangent-slot ejection. For both gas-jet and tangent-slot ejection, high coolant flow rates reduced heating even far downstream from the region of ejection; however, low coolant rates caused transition to turbulence and increased heating. Shock-layer profiles of pitot pressure, Mach number, and total temperature were reduced for both gas-jet and tangent-slot ejection. Insight into the gas-jet heat-flux mechanisms was obtained by using shock-layer rake data and established, no-cooling, heat-transfer equations.