首页> 美国政府科技报告 >A Conversion of Wheatstone Bridge to Current-Loop Signal Conditioning for Strain Gages
【24h】

A Conversion of Wheatstone Bridge to Current-Loop Signal Conditioning for Strain Gages

机译:惠斯通电桥转换为应变计电流环信号调理

获取原文

摘要

Current loop circuitry replaced Wheatstone bridge circuitry to signal-condition strain gage transducers in more than 350 data channels for two different test programs at NASA Dryden Flight Research Center. The uncorrected test data from current loop circuitry had a lower noise level than data from comparable Wheatstone bridge circuitry, were linear with respect to gage-resistance change, and were uninfluenced by varying lead-wire resistance. The current loop channels were easier for the technicians to set up, verify, and operate than equivalent Wheatstone bridge channels. Design choices and circuit details are presented in this paper in addition to operational experience.