首页> 美国政府科技报告 >Mechanical Properties Degradation of Teflon(Trademark) FEP Returned from the Hubble Space Telescope
【24h】

Mechanical Properties Degradation of Teflon(Trademark) FEP Returned from the Hubble Space Telescope

机译:从哈勃太空望远镜返回的聚四氟乙烯(商标)FEp的机械性能退化

获取原文

摘要

After 6.8 years on orbit, degradation has been observed in the mechanical properties of second-surface metalized Teflon(Reg) FEP (fluorinated ethylene propylene) used on the Hubble Space Telescope (HST) on the outer surface of the multi-layer insulation (MLI) blankets and on radiator surfaces. Cracking of FEP surfaces on HST was first observed upon close examination of samples with high solar exposure retrieved during the first servicing mission (SM1) conducted 3.6 years after HST was put into orbit. Astronaut observations and photographs from the second servicing mission (SM2), conducted after 6.8 years on orbit, revealed severe cracks in the FEP surfaces of the MLI on many locations around the telescope. This paper describes results of mechanical properties testing of FEP surfaces exposed for 3.6 years and 6.8 years to the space environment on HST. These tests include tensile testing, surface micro-hardness testing, and bend testing.