首页> 美国政府科技报告 >Sensitivity of Force Specifications to the Errors in Measuring the Interface Force
【24h】

Sensitivity of Force Specifications to the Errors in Measuring the Interface Force

机译:力度规格对测量界面力误差的敏感性

获取原文

摘要

Force-Limited Random Vibration Testing has been applied in the last several years at the NASA Goddard Space Flight Center (GSFC) and other NASA centers for various programs at the instrument and spacecraft level. Different techniques have been developed over the last few decades to estimate the dynamic forces that the test article under consideration will encounter in the flight environment. Some of these techniques are described in the handbook, NASA-HDBK-7004, and the monograph, NASA-RP-1403. This paper will show the effects of some measurement and calibration errors in force gauges. In some cases, the notches in the acceleration spectrum when a random vibration test is performed with measurement errors are the same as the notches produced during a test that has no measurement errors. The paper will also present the results Of tests that were used to validate this effect. Knowing the effect of measurement errors can allow tests to continue after force gauge failures or allow dummy gauges to be used in places that are inaccessible to a force gage.