首页> 美国政府科技报告 >DECOVALEX I - Test Case 3: Calculation of the Big Ben Experiment - Coupled modelling of the thermal, mechanical and hydraulic behaviour of water-unsaturated buffer material in a simulated deposition hole
【24h】

DECOVALEX I - Test Case 3: Calculation of the Big Ben Experiment - Coupled modelling of the thermal, mechanical and hydraulic behaviour of water-unsaturated buffer material in a simulated deposition hole

机译:DECOVaLEX I - 测试案例3:大本钟实验的计算 - 模拟沉积孔中水不饱和缓冲材料的热,机械和水力行为的耦合模型

获取原文

摘要

PNCs large scale laboratory test with an artificial deposition hole has been simulated with finite element calculations with the code ABAQUS. The test comprised water uptake from an artificial rock and heating of a canister in a deposition hole with the diameter 1 m during 5 months. Water content, pore pressure, and total pressure in the buffer was measured during the test. The given data of the material properties were supplemented with results from own laboratory tests in order to determine parameters required for the calculation. The vapour flow process, which is not included in ABAQUS, was implemented and added to the code. After calibration of the properties of the buffer material, a completely coupled thermo-hydro-mechanical calculation of the test was done. The calculated thermal and hydraulic results were in good agreement with measured values, while the prediction of the mechanical response was less good. 13 refs, 47 figs, 8 tabs. (Atomindex citation 27:045834)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号