首页> 美国政府科技报告 >Fourth Generation Light Source Instrumentation Discussion Group Number 6.
【24h】

Fourth Generation Light Source Instrumentation Discussion Group Number 6.

机译:第四代光源仪器讨论组第6号。

获取原文

摘要

This working group on 4th Generation Light Source (4GLS) Instrumentation was a follow-up to the opening-discussion on Challenges in Beam Profiling. It was in parallel with the Feedback Systems session. We filled the SSRL Conference Room with about 25 participants. The session opened with an introduction by Lumpkin. The target beam parameter values for a few-angstrom, self-amplified spontaneous emissions (SASE) experiment and for a diffraction-limited soft x-ray storage ring source were addressed. Instrument resolution would of course need to be 2-3 times better than the value measured, if possible. The nominal targeted performance parameters are emittance (1-2(pi) mm mrad), bunch length (100 fs), peak-current (l-5 kA), beam size (10 (micro)m), beam divergence (1 (micro)rad), energy spread (2 x 10(sup (minus)4)), and beam energy (10 of GeV). These are mostly the SASE values, and the possible parameters for a diffraction-limited soft x-ray source would be relaxed somewhat. Beam stability and alignment specifications in the sub-micron domain for either device are anticipated.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号