首页> 美国政府科技报告 >Application of phosphor thermometry to a Galvanneal Temperature Measurement System
【24h】

Application of phosphor thermometry to a Galvanneal Temperature Measurement System

机译:荧光测温法在镀锌温度测量系统中的应用

获取原文

摘要

The Galvanneal Temperature Measurement System (GTMS) was developed for the American Iron and Steel Institute by the Oak Ridge National Laboratory through a partnership with the National Steel Midwest Division in Portage, Indiana. The GTMS provides crucial on-line thermal process control information during the manufacturing of galvanneal steel. The system has been used with the induction furnaces to measure temperatures ranging from 450 to 700 degrees C with an accuracy of better than +/-5 Degrees C. The GTMS provides accurate, reliable temperature information thus ensuring a high quality product, reducing waste, and saving energy. The production of uniform, high-quality galvanneal steel is only possible through strict temperature control.