首页> 美国政府科技报告 >Gas Generation During Sodium Permanganate Addition to HB-Line Phase II Filtrate Tank(U)
【24h】

Gas Generation During Sodium Permanganate Addition to HB-Line Phase II Filtrate Tank(U)

机译:高锰酸钠加入HB-Line二期滤液罐(U)时的气体产生

获取原文

摘要

HB-Line Phase II process requires the addition of sodium permanganate followed by a sodium nitrite addition to prevent the precipitation of plutonium solids in a non-geometrically safe vessel. Previous experimental work has shown this method effective. Current concerns are related to the gas generated by the reaction. Potential difficulties include tank over-pressurization and tank overflow due to foaming or eructation. It is also necessary to verify that the quantity of permanganate specified by the facility is sufficient to reach the desired endpoint in a single addition.