首页> 美国政府科技报告 >Choice of Initial Operating Parameters for High Average Current Linear Accelerators
【24h】

Choice of Initial Operating Parameters for High Average Current Linear Accelerators

机译:高平均电流直线加速器初始工作参数的选择

获取原文

摘要

Recent emphasis on alternative energy sources together with the need for intense neutron sources for testing of materials for CTR has resulted in renewed interest in high current (approximately 100 mA) c.w. proton and deuteron linear accelerators. In desinging an accelerator for such high currents, it is evident that beam losses in the machine must be minimized, which implies well matched beams, and that adequate acceptance under severe space charge conditions must be met. An investigation is presented of the input parameters to an Alvarez type drift-tube accelerator resulting from such factors. The analysis indicates that an accelerator operating at a frequency of 50 MHz is capable of accepting deuteron currents of about 0.4 amperes and proton currents of about 1.2 amperes. These values depend critically on the assumed values of beam emittance and on the ability to properly ''match'' this to the linac acceptance. (ERA citation 02:020744)