首页> 美国政府科技报告 >Infiltration and Indoor Air Quality in Energy Efficient Houses in Eugene, Oregon
【24h】

Infiltration and Indoor Air Quality in Energy Efficient Houses in Eugene, Oregon

机译:俄勒冈州尤金市节能住宅的渗透和室内空气质量

获取原文

摘要

Measurements of infiltration rates and indoor pollutant levels in houses incorporating energy-conserving measures can provide important information about the effectiveness and health effects of such measures. Twelve energy-efficient houses in Eugene, Oregon were measured for effective leakage area using blower door fan pressurization. Air exchange rates over a period of several hours were determined by tracer gas decay analysis. The results of these measurements were used in conjunction with the LBL infiltration model to predict average annual and heating season infiltration rates. Measured leakage areas and infiltration rates were found to be quite low in comparison to other groups of test houses in North America. Average specific leakage areas for the 12 houses was 2.8 cm exp 2 /m exp 2 as compared to 6.4 cm exp 2 /m exp 2 for post-1975 California housing. The average heating season infiltration rate was calculated to be 0.34 air changes per hour. Infiltration rates measured from tracer gas decay ranged from 0.08 to 0.27 air changes per hour. Indoor concentrations of radon, formaldehyde, and nitrogen dioxide were measured in four of the twelve houses. Radon levels were found to be insignificant. Nitrogen dioxide concentrations were low in all four houses, although levels in the two houses where occupants smoked were slightly elevated by comparison to the two houses without smokers. Levels of formaldehyde comparable to or half of the most restrictive existing guideline were found in all four houses. Furniture and/or building materials are believed to be the source of this pollutant. (ERA citation 06:035020)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号